Ex marking decoder

Type the marking from the equipment label: every part is explained and you see the zones where the equipment may be used. Optionally, select your zone and substance to check suitability.

Decoder

Examples:

Check against your site (optional)

The two markings on an Ex label

An Ex label usually carries two separate markings. The directive marking (the hexagon “Ex”, then the group, category and G or D, e.g. II 2G) shows legal conformity under Directive 2014/34/EU. The standard marking (starting with “Ex” and ending with the EPL, e.g. Ex db IIB T4 Gb) gives the technical detail. An “X” after the certificate number means specific conditions of use; a “U” means an Ex component that cannot be used on its own.

Zones, categories and EPLs

The ATEX directives use equipment categories; IEC standards express the same idea as equipment protection levels (EPL). Labels usually carry both.

ZoneCategoryEPL
Zone 01GGa
Zone 12 or 1GGb or Ga
Zone 23, 2 or 1GGc, Gb or Ga
Zone 201DDa
Zone 212 or 1DDb or Da
Zone 223, 2 or 1DDc, Db or Da

Types of protection

CodeType of protectionStandardLevel → EPL
dFlameproof enclosureIEC 60079-1db → Gb, dc → Gc
eIncreased safetyIEC 60079-7eb → Gb, ec → Gc
iIntrinsic safetyIEC 60079-11ia → Ga/Da, ib → Gb/Db, ic → Gc/Dc
pPressurizationIEC 60079-2pxb, pyb → Gb; pzc → Gc
mEncapsulationIEC 60079-18ma, mb, mc
oLiquid immersionIEC 60079-6ob → Gb, oc → Gc
qPowder fillingIEC 60079-5Gb
tDust protection by enclosureIEC 60079-31ta → Da, tb → Db, tc → Dc
nType n (former nA is now ec)IEC 60079-15nC, nR → Gc
opOptical radiationIEC 60079-28op is, op pr, op sh
sSpecial protectionIEC 60079-33sa, sb, sc
hNon-electrical equipmentISO 80079-36/-37EPL on the label

One item may combine several types: “db eb”, for example, means a flameproof housing with an increased-safety terminal box. A marking in square brackets (e.g. [Ex ia Ga]) describes associated apparatus installed outside the hazardous area.

Groups and temperature classes

The group tells you which substances the equipment is suitable for; the temperature class gives its maximum surface temperature. For dust, the maximum surface temperature is marked directly in °C.

ClassMaximum surface temperature
T1450 °C
T2300 °C
T3200 °C
T4135 °C
T5100 °C
T685 °C
  • IIA: IIA only (propane, acetone, toluene)
  • IIB: IIB and IIA (ethylene, ethanol, diethyl ether)
  • IIC: all gases (hydrogen, acetylene, carbon disulphide)
  • IIIA / IIIB / IIIC: flyings / non-conductive dust / conductive dust; a higher group covers the lower ones

What the decoder does not do

It explains what the marking says. It does not verify that the label is genuine, that the certificate is valid, that the specific conditions of use are met on site, or the physical condition of the equipment. Whether the zone and the substance have been determined correctly is a separate question. For sites in Turkey we check all of this in an Ex equipment compliance review.

Basis

Marking under Directive 2014/34/EU (EU ATEX guidelines §146–149), the IEC 60079-0 standard marking, the IEC 60079 standards for each type of protection, ISO 80079-36/-37, and IEC 60079-14 for equipment selection. The relationship between zones and categories is set in Annex II of Directive 1999/92/EC.

This tool is for information. For equipment selection, the certificate, the instructions and the current text of the standards apply.

Link to this tool

You are welcome to link to this tool from your website, intranet or training material. Copy the code below:

Frequently asked questions

Can “Ex-proof” equipment be used in any zone?

No. The category or EPL must suit the zone, and the group and temperature class must suit the substance. Select the zone and the substance group in the decoder to check.

The label has no EPL. What does that mean?

Older labels may not show an EPL. The decoder then derives it from the level of the type of protection (e.g. db → Gb) and says so. Check the certificate for certainty.

Why is temperature checked separately for dust?

For dust, the maximum surface temperature must not exceed two thirds of the dust cloud ignition temperature or the 5 mm layer ignition temperature minus 75 K (IEC 60079-14). Thicker layers need a separate assessment.