Who it is for
- Sites that use many chemicals, with the inventory spread across departments and spreadsheets.
- Sites whose safety data sheets are missing, out of date or inconsistent with the label.
- Stores where chemicals of different hazard classes are kept side by side.
- Sites that do not know whether they fall under the Seveso III Directive (in Great Britain, COMAH).
- Sites preparing an explosion protection document or DSEAR assessment: the inventory is its first step.
The chemical inventory
Every chemical is listed with where it is used and stored, its packaging and the maximum quantity on site, not the average stock. Hazard classes come from section 2 of the safety data sheet; flash point, explosion limits, vapour pressure and auto-ignition temperature from section 9; storage conditions from section 7; incompatible materials from section 10.
The result is one table. The explosion protection document, the risk assessment, the emergency plan, the store layout and the Seveso check all draw on it.
Safety data sheet review
The supplier who places a substance or mixture on the market prepares the safety data sheet; in the EU its content is set by Annex II of REACH. We review the sheets you hold and ask:
- Is the sheet current, and does it match the label and today's composition?
- Does section 9 give the data needed to assess the explosion risk, or does it say “no data available”?
- Do the storage and incompatibility sections (7 and 10) match what happens on site?
- Is any chemical on the inventory without a safety data sheet at all?
The gaps are listed in a form you can send to your suppliers. We do not author safety data sheets.
Storing incompatible chemicals apart
An oxidiser next to flammable liquids, an acid and a base on the same shelf, or a water-reactive substance on a damp floor can make an otherwise orderly store dangerous. We review the store by hazard class and set out which groups have to be kept apart and how. Recognised segregation rules such as TRGS 510 in Germany are the basis of the method.
Flammable liquid cabinets, spill containment, the daily quantities kept in production areas and store ventilation are part of the review.
Seveso III threshold check
The Seveso III Directive (2012/18/EU) applies to establishments holding dangerous substances above the thresholds in its Annex I, based on the maximum quantity that can be present at any one time. For example, the lower- and upper-tier thresholds are 5 and 50 tonnes for hydrogen, 50 and 200 tonnes for liquefied flammable gases including LPG, and 2,500 and 25,000 tonnes for petroleum products such as petrol and diesel.
Substances that are each below their own threshold can still bring a site into scope together. The aggregation rule adds up the ratios of quantity to threshold separately for health, physical and environmental hazards. Example: 3 tonnes of hydrogen and 30 tonnes of LPG give 3/50 + 30/200 = 0.21 against the upper-tier thresholds, but 3/5 + 30/50 = 1.2 against the lower-tier thresholds, so the site is a lower-tier establishment although neither substance reaches its own threshold.
We prepare the scope and tier calculation with its justification. A safety report and a major-accident prevention policy are separate pieces of work.
What you receive
- Chemical inventory table: location, maximum quantity, hazard classes and physical data.
- SDS checklist and the list of data to request from suppliers.
- Segregation table and a proposed store layout.
- Seveso III scope and tier calculation, with its justification.
- A signed report; every page carries a QR code that shows whether it is genuine and unchanged.
How it works
Send the list and the sheets
Your chemical list, the safety data sheets and photos or a plan of the store.
Free first look and fixed price
Within one working day: first observations and a fixed-price offer based on the number of chemicals and storage areas.
Inventory and review
Questions to your team where quantities or sheets are missing.
Report
The inventory table, the checklists, the segregation table and the Seveso calculation.
Scope, fees and timeline
| Item | Typical time |
|---|---|
| Chemical inventory and SDS review | Agreed in the offer |
| Storage compatibility review | Agreed in the offer |
| Seveso III scope and tier calculation | Agreed in the offer |
We send a fixed-price offer within one working day of seeing your documents. The price depends on the number of sources of release, the documents and drawings available, and the scope you choose; there are no hourly rates. Quotations exclude taxes.
Basis of our work. Our work is based on the documents, drawings and data you provide. On-site verification is the client's responsibility, and our work does not replace it; for sites in Türkiye, the proposal can include it. Every report lists the documents it relies on and the assumptions made where information was missing.
Frequently asked questions
Will you write our safety data sheets?
No. The supplier who places the substance or mixture on the market prepares the safety data sheet. We review the sheets you hold and list the missing or inconsistent sections in a form you can send to the supplier.
How do we know whether we fall under Seveso III?
The maximum quantities of all dangerous substances that can be present at any one time are listed, compared with the Annex I thresholds, and the aggregation rule is applied separately for health, physical and environmental hazards. If any result is 1 or more, the establishment is in scope; the same calculation decides lower or upper tier.
Is the inventory only for the explosion protection document?
No. The same inventory feeds the chemical risk assessment, the emergency plan, the store layout and the Seveso check. Once it is set up correctly, the yearly update is quick.
Can you do this without visiting the site?
Yes, from your list, the safety data sheets and photos of the store; what we could not verify is stated in the report. For sites in Türkiye, a site visit can be included in the offer.