Explosion protection for spray booths and paint shops

Every booth where solvent-based paints and thinners are used should be assessed. The inside of the booth, the exhaust duct, the paint mixing area and the thinner store are taken together, because a decision for one affects the others.

Where the explosion risk comes from

During spraying, the solvents in paint and thinner evaporate. The fine droplets, or mist, produced by spraying can ignite even below the flash point of the liquid. The safety of a booth therefore depends largely on the exhaust running adequately and continuously.

Sources of release

  • Inside the booth and around the spray gun
  • Exhaust duct and filters
  • Booth openings and exhaust outlet
  • Paint preparation and mixing
  • Paint and thinner store
  • Dirty rags and waste containers
  • Drying zone

In powder coating booths the hazard is combustible dust, and the assessment uses dust zones.

What we look at closely

With the exhaust running, the average solvent concentration in a booth is often a small fraction of the lower explosive limit. The real question is what happens when the exhaust stops or the filters clog. We therefore write the interlock between exhaust and spray gun, and the filter change regime, into the report as conditions of the zone decision, and into the control plan.

How we assess it

  1. Chemicals. Flash point, explosive limits and composition are taken from the safety data sheets of the paints, thinners and cleaning solvents, together with the daily quantities used.
  2. Exhaust flow. The booth exhaust flow is measured or taken from documents, and the drop in flow as the filters load up is established.
  3. Concentration. The average solvent concentration in the booth during spraying is calculated as a percentage of the lower explosive limit (%LEL).
  4. Interlocks. The effect on the zone decision of measures such as an interlock that stops the gun when the exhaust is off, and of monitoring, is assessed. These conditions are written into the control plan.
  5. Ignition sources. Lighting and the fan motor inside the booth are assessed. Earthing and static electricity are checked for the gun, containers, workpieces, floor and operator.

Gaps worth checking

  • The whole inside of the booth written down as Zone 1, or as no zone at all, without reasoning.
  • Exhaust flow never measured, and the filter change regime not tied to the zone decision.
  • The paint mixing area and the thinner store left out.
  • Earthing of workpieces lost through paint build-up on hangers.
  • Dirty rags and paint waste kept in open containers.
  • Electrical equipment outside the booth not checked against the openings and the exhaust outlet.

What we need from you

  • Booth manufacturer's technical file and declaration of conformity
  • Safety data sheets for paints, thinners and solvents
  • Quantities used
  • Exhaust fan data and any measurement report
  • Ex certificates of the equipment inside the booth
  • Earthing test report

What you receive

The %LEL and ventilation calculation, and zone drawings for the booth and its surroundings. With them come a control plan for conditions such as the interlock and filter changes, static electricity measures, and area rules to post at the booth door.

Rules in your country

  • Europe. Spray booths are machinery: EN 16985 sets the safety requirements for their design, and the zones and conditions the manufacturer specifies are taken into the site's assessment.
  • Great Britain. The booth, the mixing room and the store are part of the DSEAR risk assessment and its zone classification.
  • Germany. The zones go into the Explosionsschutzdokument (§ 6(9) GefStoffV).
  • Netherlands. The zones go into the explosieveiligheidsdocument as part of the RI&E; gas and vapour zoning normally follows NPR 7910-1.
  • United States. Spray finishing with flammable materials falls under OSHA 29 CFR 1910.107, and NFPA 33 covers spray application. On request we classify to NFPA 497 with the Division system.
  • Türkiye. The zones go into the explosion protection document required by the 2013 regulation, and we work on site.

Questions

We use water-based paint. Is an assessment still needed?

Most water-based paints still contain some flammable solvent. The decision rests on the flash point and the composition in the safety data sheet. Thinners, cleaning solvents and other chemicals are assessed as well.

The booth manufacturer gave us a declaration of conformity. Is that enough?

The manufacturer's declaration concerns the design of the booth. How the booth is used at your site, with which paints, in what quantities, with what maintenance and in what surroundings, is assessed in the explosion protection document. Zones and conditions the manufacturer has specified for the booth are taken into the report.

This page is general information. The result for your site is set by calculations based on your site data.